Anatomical registration of intracranial electrodes. Robust model-based localization and deformable smooth brain-shift compensation methods

Go to Publication »

J Neurosci Methods. 2024 Jan 13:110056. doi: 10.1016/j.jneumeth.2024.110056. Online ahead of print.

ABSTRACT

BACKGROUND: Intracranial electrodes are typically localized from post-implantation CT artifacts. Automaticalgorithms localizing low signal-to-noise ratio artifacts and high-density electrode arrays are missing. Additionally, implantation of grids/strips introduces brain deformations, resulting in registration errors when fusing post-implantation CT and pre-implantation MR images. Brain-shift compensation methods project electrode coordinates to cortex, but either fail to produce smooth solutions or do not account for brain deformations.

NEW METHODS: We first introduce GridFit, a model-based fitting approach that simultaneously localizes all electrodes’ CT artifacts in grids, strips, or depth arrays. Second, we present CEPA, a brain-shift compensation algorithm combining orthogonal-based projections, spring-mesh models, and spatial regularization constraints.

RESULTS: We tested GridFit on ~6000 simulated scenarios. The localization of CT artifacts showed robust performance under difficult scenarios, such as noise, overlaps, and high-density implants (<1mm errors). Validation with data from 20 challenging patients showed 99% accurate localization of the electrodes (3160/3192). We tested CEPA brain-shift compensation with data from 15 patients. Projections accounted or simple mechanical deformation principles with <0.4mm errors. The inter-electrode distances smoothly changed across neighbor electrodes, while changes in inter-electrode distances linearly increased with projection distance.

COMPARISON WITH EXISTING METHODS: GridFit succeeded in difficult scenarios that challenged available methods and outperformed visual localization by preserving the inter-electrode distance. CEPA registration errors were smaller than those obtained for well-established alternatives. Additionally, modeling resting-state high-frequency activity in five patients further supported CEPA.

CONCLUSION: GridFit and CEPA are versatile tools for registering intracranial electrode coordinates, providing highly accurate results even in the most challenging implantation scenarios. The methods are implemented in the iElectrodes open-source toolbox.

PMID:38224783 | DOI:10.1016/j.jneumeth.2024.110056